Online Analyzers

Online Analyzers
ppsmumbai

Products Description

gaZpro Ox Online Analyzer

Features :

Control Card : Solid State Electronics Base
 Range  : Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)
 Resolution : Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)
 Display : 3 ½ Digit LED
 Size  : Standard Enclosure Size: H: - 200 mm W: - 180mm D: - 320 mm
 Oper. Temperature  : 0 – 50 deg C
 Visual Indication : A) Pilot B) Warn C)  Alarm
 Controls : Optional: - A) Reset B) Accept
 Parameter Setting   : A) Zero B) Span C) Warn D) Alarm
 Input Signals  :  Standard: - 4 – 20 mA.
Optional: - 0 – 1 Vdc
 Outputs : Standard: - 4 – 20mA. Recorder Output, Potential free Relay contacts for Alarms. Optional: - Repeater output for Alarms, 0 – 1 vDC. Recorder Output
 Power Supply  : Standard: - 220 vAC. 50 Hz
Optional: - 110 vAC. 50 Hz
 Mounting  : Standard: Panel Mounting
Mounting  : Standard: Panel Mounting
 Flow : 100 – 200 ml / min.
 Pressure : Gas Pressure on Sensor head should not exceed 1 Kg. / cm2
 Connections : Standard: - ¼ “ NPT for 1/P and O/P
Optional: - As per specifications
Sensor Type : Electrochemical
 Sensor Life : Max. 2 years (in fresh air)
 Response Time : 90% of FSD in <30 Sec.

Request Quote
Online Analyzers

Products Description

gaZpro Ox - FLP Online Analyzer

Explosion proof version for application in II A/B, IIC

Features :

Control Card : Solid State Electronics Base
 Range  : Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)
 Resolution : Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)
 Display : 3 ½ Digit LED
 Size  : Standard Enclosure Size: H: - 200 mm W: - 180mm D: - 320 mm
 Oper. Temperature  : 0 – 50 deg C
 Visual Indication : A) Pilot B) Warn C)  Alarm
 Controls : Optional: - A) Reset B) Accept
 Parameter Setting   : A) Zero B) Span C) Warn D) Alarm
 Input Signals  :  Standard: - 4 – 20 mA.
Optional: - 0 – 1 Vdc
 Outputs : Standard: - 4 – 20mA. Recorder Output, Potential free Relay contacts for Alarms. Optional: - Repeater output for Alarms, 0 – 1 vDC. Recorder Output
 Power Supply  : Standard: - 220 vAC. 50 Hz
Optional: - 110 vAC. 50 Hz
 Mounting  : Standard: Panel Mounting
Mounting  : Standard: Panel Mounting
 Flow : 100 – 200 ml / min.
 Pressure : Gas Pressure on Sensor head should not exceed 1 Kg. / cm2
 Connections : Standard: - ¼ “ NPT for 1/P and O/P
Optional: - As per specifications
Sensor Type : Electrochemical
 Sensor Life : Max. 2 years (in fresh air)
 Response Time : 90% of FSD in <30 Sec.
 Hazardous Protection : Explosion proof version for application in IIA/IIB, IIC

Request Quote